Modem 2500
Artikel Nr. Modem 2500
EASYBUS monitoring system from the distance - Greisinger electronic -
EASYLOG - Remote pickup system
for EASYLOG- signal logger
By means of the software GSOFT 40K it is possible, besides of serving data loggers
on site to configurate and read out
signal loggers which are
far away from the operation place
and which are solely connected via MODEM with the
telephone net.
There is no extra computer necessary!
Simple construction:
Work place:
GSOFT 40K
with analog standardized modem
remote pickup
site:
with industrial modem
MODEM
2500 and
EASYBUS interface converter
(e.g. EBW 1)
When executing the order "connect logger" a local
serial interface or a telephone connection is being opened, according to your
configuration.
Reading out the logger lasts hardly longer than usual, the compete
logger-handling is also given via telephone connection.
As work place modems customary analog modems are being
assisted, which can also be connected with an ISDN connection via
terminal adapter.
The industrial modem of the remote pickup
site
is an industrial modem (MODEM 1000, MODEM 2500, MODEM 3500 GSM) specially designed for EASYBUS.
Expanded setup with alarm via SMS:
As a special service it is possible to send an SMS in case of alarm, e.g.
when using a EB2000MC/EB3000 together with an interface converter
(EBW 1, EBW 64, EBW
240).
You will automatically receive a message on your handy, e.g. when temperature
rises above a certain level.
Work place:
GSOFT 40K
with analog standardized modem
remote pickup
site:
with industrial modem MODEM
2500
with alarm function and EB 2000 MC
(resp. EBUW 232A + EBW...)
One resp. the alarm outputs of components used are being connected with the alarm
input of the MODEM. In case of alarm a prepared message
is being sent as
SMS then.
In order to examine the cause of the alarm more detailed, the measuring and
loggered values can be read out by means of the software GSOFT 40K.
Remote pickup via D1 or D2 Mobile net:
In case there is no local telephone connection on
site or for a mobile setup, remote
pickup is also possible via the wireless MODEM 3500 GSM,
supporting
the D1 and D2 net.
This modem works as a mobile telephone with integrated MODEM.
Common SIM-cards are being used.
The only necessity is a permission for data transmission by the net provider
Your advantages:
With the EASYBUS remote pickup system a variable
quantity of remote
pickup sites can be controlled from one or more working sites.
Expensive
journeys over hundreds of kilometers can be avoided, you can control all
measuring values from your office.
The installation and set up requires minimum effort.GSOFT40K handling is as easy as you are being used.
The comfortable configuration software
MODKonfig included in GSOFT40K supports you in installing
your
industrial modem - even without any knowledege of signal remote
transmission you are ableto start a reliable system within minutes.
Components for the EASYLOG-Remote
pickup system:
Modem 1000
MODEM 1000:
analogue standard-industrial modem with password protection for EASYBUS-
remote pickup via analogue telephone net.
(plug-in power pack, TAE-cable, 25-pol. Dsub-cable and GSA-25S-9B included)
MODEM 2500:
analogue hat rail MODEM with alarm input and SMS-alarm for
EASYBUS-remote pickup via analogue telephone net.
Modem
3500 GSM
MODEM 3500 GSM:
GSM-Modem (for D1 or D2) with password protection and SMS-alarm,
for
EASYBUS-remote pickup via the 900 MHz-wireless net
(Voltage: 10 ... 60 VDC, 9-pin Dsub-cable included, antenna
has to be
ordered separately)
Antenna 3500 GSM
Antenna 3500 GSM:
Dualband-industrial antenna with mounting support
DFM 232 SET
DFM 232 SET:
Data remote pick up modul set, 433 MHz, consisting of sending
unit and receiver
for the wireless pick-up of EASYBUS-modules
via a 433 MHz- radio-controlled net
Bidirectional RS 232 interface (DB-9), e.g. for connection with EBW1,
high range of up to 1.500 free sight, range within buildings similar to
DECT
LAN 3000
LAN 3000:
for
EASYBUS-remote pickup via LAN or internet
serial RS 232 input (DB-9), e.g. for EBW1, 1x LAN Port RJ-45 10/100 Mbps
reports assisted: TCP, DHCP, HTTP...
network connection via: Stat. IP, DHCP or PPPoE
GNG 12/300:
Hat-rail power pack for MODEM 2000 HS / MODEM 3000 GSM
GNG 12 - LE:
plug-in power pack for MODEM 2000 HS / MODEM 3000 GSM
GSK 9S-9S-NM:
zero modem cable (9-pin) for connecting a MODEM.. to a
EBW 1
up to EBW 240
GRS 01/9 - NM:
Interface-adapter RS 232 for connecting a MODEM ... to a
EB 2000 MC.
EBUW 232A
EBUW 232A:
Alarm monitor module and report converter for EASYBUS
The EBUW232A monitors up to 240 EASYBUS-modules
and
checks them up referring to alarm given.
In case of an alarm the alarm
output of the EBUW is set.
In addition a switching module EBB4out can be
reached
(Max-, Min- and system alarm are possible).
Furthermore the EBUW232A acts as a report converter,
reconstructing
splitted RS232-enquiries
(e.g. by a modem-connectionand makes them
understandable
for EASYBUS-converter and final devices)
The EBUW232A is simply plugged between the EASYBUS-interface converter
and the demanding device (MODEM / PC) by the adapter cable included.
Power supply: 6-12 V DC, max. 10 mA (via adapter cable)
Switching output: NPN-open collector, max. switching performance:
24 V, 50 mA
GNR 232 A:
Power supplay and relay module for EBUW232A
Input: 230V, 50/60 Hz,
Output: 12 V DC +5% (stabilised) 25 mA
Connection: screw-type terminal
Relay output: voltage-free converter, switching power max. 10 A
Ohmic load
Dimensions: 96 x 61 x 60 mm (HxWxD)
GNG 10 - LE:
Plug-in power supply 10V/10mA
(for applications, where the
switching output is not used or used directly.
Analog top hat rail modem with alarm input and SMS alarming for remote pick-up of EASYBUS modules via the analogous phone web. Price upon request!
= data sheet as *.pdf
deutsche Beschreibung
Your article: Modem 2500;
Article No. Modem 2500.
The total price of the article is: EUR
The net price of the article Modem 2500
is: EUR 496.64